Data Controller |
The 7044000-1 Data Controller collects, processes, and stores vibration data information from Techkor wireless sensors. Data Controller does not requires any installations on client computers for startup. Operators can monitor wireless sensor data, be informed of alarm conditions, and configure parameters all from the convenience of standard PCs using Microsoft Internet Explorer. As an Ethernet node the unit features typical 10/100/1000Mbps base-T Ethernet, TCP/IP, FTP, HTTP, SSH and Telnet accessibility. 7044000-1 hosts Vibration Monitoring MYSQL5 database, HTTP, FTP, SSH, NTP and basics network servers.
For easy configuration, the 7044000-1 is remotely accessible over computer network or directly. Over the network, configuration is available through easy to use WEB interface. Operators may also configure or monitor the unit locally by connecting a standard VGA monitor and keyboard, or through SSH/Telnet connection.
In installations requiring more than one Data Controller one is configured as a master unit while the others are configured as a client controller. Client controllers send vibration to database located in master controller. Client controller does not require HDD.
| Parameter | Min. | Typ | Max | Units |
|---|---|---|---|---|
| CPU Clock Frequency | 1.1 | 1.1 | 1.6 | GHz |
| Real Time Clock Life | 10 | Years | ||
| Memory, DRAM | 256 | 512 | 2048 | Mbyte |
| Compact Flash/Micro Drive | 2 | 2 | 8 | GByte |
| SATA HDD | 20 | 80 | 160 | GByte |
| Ethernet Rate | 1000 | Mbit/s | ||
| Power Supply Power | 20 | W | ||
| Weight | 0.5 | kg | ||
| AC Input Voltage | 100 | 240 | VAC | |
| AC Input Frequency | 47 | 63 | Hz | |
| Operating Temperature | 0 (32) | 45 (113) | °C (F) | |
| Storage Temperature | -20 (-4) | +80 (176) | °C (F) | |
| Operating Humidity, non-condensing | 10 | 90 | % |
| Part Number: | 7044000-1 | Data Controller (1.6GHz/RAM1GB) |

Rev A.5. Specifications are subject to change without notice.
|
© 2010 Techkor Instrumentation. All rights reserved.
Specifications are subject to change without notice. Contact us by email |